Primary Voltage: 6.3KV-35KV or Others
Secondary Voltage: 0.12KV-0.6KV or Others
Connection Type: Dyn11/YNyn0 or Others
Standards: ANSI/IEEE, CSA/CAN, DOE
Rated Power 112.5 KVA
112.5 KVA Three Phase Pad Mounted Transformer
Phase: Three Phase
Frequency 50Hz/60Hz
Rated Power 112.5 KVA
Main Voltage 13,200V Y/7,200V Wye-N
Voltage Class: 15 KV
Connection Type: Wye-N
Main Insulation Class: 95 KV
Main FCAN Taps: 2 x 2.5%
Main FCBN Taps: 2 x 2.5%
HV Fuse: Standard Bay-O-Ney
Load Switch: LBOR
Lightning Arrester Dead End
Secondary Voltage: 208V Y/120V Wye-N
Auxiliary connection: Wye-N
Loss No-load: 60 watts, Load loss: 1 873 watts
112.5 KVA Three Phase Pad Mounted Transformer
112.5 KVA Three Phase Pad Mounted Transformer is a highly efficient and environmentally friendly power conversion equipment. Its primary voltage is 13500Y/7200 V Wye-N and secondary voltage is 208Y/120 V Wye-N. The 112.5 KVA transformer adopts advanced cold-rolled silicon steel sheet core and mineral oil cooling system with a temperature rise of 65°C, ensuring low heat generation and high cooling efficiency during operation. The NEMA 3R enclosure makes it suitable for indoor and outdoor installations, and the rugged and reliable structure is suitable for various power distribution needs. Its high efficiency not only reduces energy costs, but also extends the equipment life and reduces the total cost of ownership.
Efficient cooling: The mineral oil cooling system and low temperature rise design enable the transformer to maintain efficient operation under high load conditions.
Energy saving and environmental protection: By reducing energy consumption and heat emissions, it achieves higher environmental protection standards and meets modern energy-saving requirements.
Durable design: The materials and processes used can extend the service life of the transformer and reduce the failure rate.
Flexible installation: The NEMA 3R enclosure and pad-mounted design make the transformer suitable for a variety of installation environments, providing greater flexibility.
Installation: Follow the instructions of the power engineer during the installation process to ensure the correct wiring and safe installation of the transformer.
Operation: Check the oil level and electrical connections regularly to ensure the normal operation of the transformer.
Maintenance: Perform regular maintenance and inspections according to the manufacturer’s recommendations to maintain optimal performance of the equipment.
High Pressure Bushings: 3
Low Pressure Bushings: 4
Oil Level Indicator: 1
Pressure Relief Valve: 1
Radiator: Typically 2-4, depending on design
Maintenance: 1
Cooling Fans: If present, typically 2-4
Thermometer: 1
Ground Terminal: 1
Tap Converter: 1