Low-voltage switchgear GGJ Low-Voltage Reactive Power Intelligent Compensation Device

GGJ Low-Voltage Reactive Power Intelligent Compensation Device

Rated voltage<1kV
Rated Frequency50Hz
Application scenariosWidely used in low-voltage power grids, dedicated to free power compensation of three-phase transformers with a capacity of 130-600KVA

Overview 

The GGJ low voltage reactive intelligent compensation device introduces microcomputer control by adopting computer- aided design (CAD),and carries out intelligent tracking compensation for reactive power.With reasonable structure and  advanced technology,it is widely used in low-voltage power grid,to enhance power factor,reduce reactive loss and improve power supply quality.As a new generation power saving product,it is specially used in the 130-600kVA three- phase transformer for reactive power compensation.

Features

+Controlled   by   intelligent   controller,full-featured.Reliable   performance,automatic   compensation;can   increase   the    power factor to 0.9 even higher.

+Real-time  display  of  grid  power  factor  and  range:lag  (0.00-0,99),ahead  (0.00-0.99).

+With    over-voltage,over-harmonic,over-compensation,system    failure,lack    of    phase,overload     and    other    comprehensive protection

+The  parameters  which  have  been  set  will  not  lose  after  power  failure,and  it  automatically  enters  into  running  mode power  grid  becoming  normal  without  operators  watching  over.

+According  to  the  grid  load  balance,take  phase  compensation  or  mixed  compensation.

+Strong  anti-interference  ability,can  withstand  the  interference  pulse  with  an  amplitude  of  2000V  directly  input  from grid,which  is  higher  than  the  national  professional  standards.

Environmental Conditions

a   Altitude:≤2000m

b   Installation  environment:free  of  harmful  gases  and  steam,conductive  or  explosive  dust  and  serious  mold.

C   Relative    humidity:≤90%at   20℃

d   Ambient  temperature:-20°℃~+45°℃

Distribution Network Detection Function

a  Real-time  measurement  and  hourly  record  of three-phase  voltage,current,frequency,active  power,reactive  power, power factor,active energy and reactive energy at transformer’s LV side;voltage and current overall distortion rate and 2-25 subharmonic capacity.

b  RS-232 and RS-485 interface is equipped to handle computer data transcription.Also it can achieve wireless metereading,device testing,parameter settings and realtime data measurement and the reading of recorded data functions through the remote communication.

C Data analysis function:carry out analysis and process,as well as statistical query on operating load data;comprehensively analyze power supply quality,calculate voltage qualification rate,power supply load rate and reliability and max.load rate;inspect power factor,active power and reactive power at different period of time;make the diagram of voltage,current and power factor of each phase;print synthetic analysis and statistics report.

 

Performance parameters